p styletext-align: justify;strongspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体 创新动因:/span/span/strongspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体热处理车间新中频/spanspan stylefont-family:宋体4月12日新中频报警,初步判断是西门子驱动损坏故障,4 月15日下午5点在购买西门子驱动安装后,依旧有报警,因为影响到三装供货,必须尽快修复。/span/span/pp stylemargin-bottom: 0px; margin-top: auto; text-align: justify;strongspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体 创新措施:/span/span/strongspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体首先安装新驱动参数。/span/span/pp stylemargin-left: 48px; text-align: justify;span stylefont-family:Calibri;font-size:19px1、 /spanspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体根据报警/spanspan stylefont-family:Calibri25201/spanspan stylefont-family:宋体轴/spanspan stylefont-family:CalibriMY1/spanspan stylefont-family:宋体伺服故障,/spanspan stylefont-family:Calibri25000/spanspan stylefont-family:宋体轴/spanspan stylefont-family:CalibriMY1/spanspan stylefont-family:宋体主动编码器硬件故障分析,报警原因是西门子驱动、西门子伺服电机、西门子电缆线引起的。/span/span/pp stylemargin-left: 48px; text-align: justify;span stylefont-family:Calibri;font-size:19px2、 /spanspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体驱动已更换,把/spanspan stylefont-family:CalibriY/spanspan stylefont-family:宋体轴伺服电机和/spanspan stylefont-family:CalibriX/spanspan stylefont-family:宋体轴伺服电机互换,报警依旧在/spanspan stylefont-family:CalibriY/spanspan stylefont-family:宋体轴,故判断西门子伺服电机正常。/span/span/pp styletext-align: justify;span style;font-family:宋体;font-size:19pxspan stylefont-family:宋体开始判断电缆线故障,首先对/spanspan stylefont-family:CalibriY/spanspan stylefont-family:宋体轴和/spanspan stylefont-family:CalibriZ/spanspan stylefont-family:宋体轴编码器电缆线互换,/span/span/pp stylemargin-bottom: 0px; margin-left: 48px; margin-top: auto; text-align: justify;span style;font-family:宋体;font-size:19pxspan stylefont-family:宋体互换后判断/span/spanspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体电缆线确定已损坏。/span/span/pp stylemargin-bottom: 0px; margin-left: 48px; margin-top: auto; text-align: justify;strongspan stylefont-family:Calibri;font-size:19px创新效果:/span/strongspan stylefont-family:Calibri;font-size:19px1、 /spanspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体首先用万用表测量电缆线两端插头,又根据图纸,确定电缆线/spanspan stylefont-family:Calibri7/spanspan stylefont-family:宋体根线中其中一根已断。/span/span/pp stylemargin-bottom: 0px; margin-left: 48px; margin-top: auto; text-align: justify;span stylefont-family:Calibri;font-size:19px2、 /spanspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体外接一根无法解决报警,然后又一点一点一段一段开始排查测量,找出断点。最后在线槽处电缆开裂,折断,连接后机床正常。/span/span/pp stylemargin-bottom: 0px; margin-left: 48px; margin-top: auto; text-align: justify;span stylefont-family:Calibri;font-size:19px3、 /spanspan style;font-family:宋体;font-size:19pxspan stylefont-family:宋体又进行了参数调整,修好后已是夜里/spanspan stylefont-family:Calibri12/spanspan stylefont-family:宋体点多。/span/span/ppbr//p